DataLogger SETIER Flowmeter V0.0 Hardware EN

alternate text

Attention

We invite you to refer to this document to assemble Datalogger SETIER V0.00 FLOWMETER Hardware Part.

Attention

SETIER is a participative project open to all, it requires skills in electronics and to respect the safety rules. SETIER must be assembled in a professional context and by people competent in electronics. The SETIER team cannot be held responsible for any material or human damage which would be associated with the use or the assembly of Datalogger SETIER. The SETIER team cannot be held responsible if the equipment does not work after assembly. You may redistribute and modify this documentation and make products using it under the terms of the CERN-OHL-P v2 (https:/cern.ch/cern-ohl). This documentation is distributed WITHOUT ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING OF MERCHANTABILITY, SATISFACTORY QUALITY AND FITNESS FOR A PARTICULAR PURPOSE. Please see the CERN-OHL-P v2 for applicable conditions.You may redistribute and modify this documentation and make products using it under the terms of the CERN-OHL-P v2 (https:/cern.ch/cern-ohl). This documentation is distributed WITHOUT ANY EXPRESS OR IMPLIED WARRENTY, INCLUDING OF MERCHANTABILITY, SATISFACTORY QUALITY AND FITNESS FOR A PARTICULAR PURPOSE. Please see the CERN-OHL-P v2 for applicable conditions.

Technical Data

That data represent different using parameters of the flowmeter datalogger.

Parameters

Specifications

Units

Supply voltage (VCC)

7 to 15

V

Effective measuring range

100 to 1500

mm

Accuracy

1

mm

Resolution

0.1

mm

error percentage

+/- 0.1

%

Temperature resolution

0.1

°C

Temperature error

+/-1

°C

Using temperature

-20 to 80

°C

Measurement frequency

30

Hz

Emission cone

12 +/-2

°

Sealing standard

IP65

Communication interface

RS485

Data storage

micro SD card

Datalogger Assembly

Step 1 : Electronic part assembly

The first part consists of assembling the different electronic board together.

Material List

Name

How Many

Picture

MKR MEM Shield

1

_images/MKR_SD.JPG

MKR Connector Carrier

1

_images/MKR_CARRIER.JPG

MKR WIFI 1010

1

_images/MKR_WIFI.JPG

µSD card

1

_images/SD.JPG

RS485 communication board

1

_images/RS485.JPG

RTC Module

1

_images/RTC.JPG

Voltage divider board

1

_images/VOLTAGE.JPG

CR1220 lithium battery

1

_images/Battery.JPG
  1. Connect the MKR MEM Shield on the MKR Connector Carrier.

    alternate text
  2. Connect the MKR WIFI 1010 on the MKR MEM Shield.

    alternate text
  3. Insert the µSD card inside the MKR MEM SHIELD.

    alternate text
  1. Take the RS485 communication board and connect its wire on.

    alternate text
  2. Connect the other side of the wire from the RS485 communication board to the SERIAL port of the MKR CONNECTOR CARRIER.

    alternate text
  3. Take the RTC module and plug its wire on.

    alternate text
  4. Take the CR1220 lithium battery and insert it on the RTC module.

    RTC_battery
  5. Connect the other side of the wire from the RTC module to the TWI port of the MKR CONNECTOR CARRIER.

    alternate text
  6. Take the voltage divider board and plug its wire on.

    alternate text
  7. Connect the other side of the wire from the voltage divider board to the A5-A6 of the MKR CONNECTOR CARRIER.

    alternate text

Step 2 : Mechanical assembly

Material list

Name

How many

Picture

PVC support

1

_images/PVC_Flow.JPG

Box 201x163x98mm

1

_images/flow_Box.JPG

SEN0358 sensor (distance) -external diameter 20 mm

1

_images/SEN0358.JPG

Spacer (M2 et M3) 20 mm long

+/-10 of each

_images/entretoise.JPG

Screw (M2 et M3)

+/-10 of each

_images/vis.JPG

Nuts (M2 et M3)

+/-10 of each

_images/ecrou.JPG

12 cm red/black multi-strand cable diameter 1,6 mm

1 of each color

_images/cable-fin.JPG

12 cm red/black multi-strand cable diameter 3 mm

1 of each color

_images/cable-%C3%A9pais.JPG

Crimp lug

2

_images/Pod.JPG

Red banana plug (external diameter 12 mm)

1

_images/Red_Banana.JPG

Black banana plug (external diameter 12 mm)

1

_images/Black_Banana.JPG

Voltcraft power supply

1

_images/Alimentation.JPG

male µ USB/male USB-A wire

1

_images/USB-Cable.JPG

Push button (external diameter 14 mm)

1

_images/Bouton.JPG

Grove screw terminal

1

_images/Screw_Gr.JPG
  1. Take a piece of wood, PVC, or some other non-conductive element, and cut it following the folder “Flowmeter_datalogger_hole.pdf” to do the fixing plate of the different datalogger board. Drill hole to put on the spacer inside it, then fix it.

    alternate text
  2. Drill a 20 mm diameter hole inside the box 201x163x98mm following the folder “Flowmeter_datalogger_hole.pdf”.

    alternate text
  3. Insert the SEN0358 sensor inside the box hole, and fix it with one nuts on both side of the box (the nuts are provided with the sensor).

    alternate text
  4. Fix the Arduino MKR Carrier on the spacer provided for that purpose, with some screw (following the folder “Flowmeter_datalogger_hole.pdf”).

    alternate text
  5. Fix the RTC module on the spacer provided for that purpose with some screw (following the folder “Flowmeter_datalogger_hole.pdf”).

    alternate text
  6. Fix the Grove screw terminal on the spacer provided for that purpose with some screw (following the folder “Flowmeter_datalogger_hole.pdf”). This module must be put on top of the RTC module.

    alternate text
  7. Fix the PVC plate on the bottom of the box, with screw, by routing the sensor wire through the PVC plate hole.

    alternate text
  8. Take an independant red wire, and the brown wire from the SEN0358 sensor, and connect them both inside the VOL port of the voltage divider board. Screw them.

    alternate text
  9. Take a independant black wire, and the black wire from the SEN0358 sensor, and connect them both inside the GND port fo the voltage divider board. Screw them.

    alternate text
  10. Take the RS485 communication board and connect the SEN0358 sensor wire inside using a flat screwdriver : the blue wire must be connect on the B port and the wire must be connect on the A port.

    alternate text
  11. Fix the RS485 communication board on the spacer provided with screw.

    alternate text
  12. Fix the voltage divider board on the spacer provided for that purpose. This module must be put on top of the RS485 communication board.

    alternate text
  13. Drill two 12 mm diameter hole on one side of the box. Take one red banana plug and black banana plug. Insert it inside that hole, then fix it (a nuts is provided with the banana plug).

    alternate text
  14. Cut 12cm of red wire diameter 3 mm. Use a wire stripper to strip 1 cm on both side of the wire.

    alternate text
  15. Cut 12cm of black wire diameter 3 mm. Use a wire stripper to strip 1 cm on both side of the wire.

    alternate text
  16. Take a crimp lug. Use a crimping tool to fix the crimp lug on one side of the red wire diameter 3 mm.

    alternate text
  17. Take a crimp lug. Use a crimping tool to fix the crimp lug on one side of the black wire diameter 3 mm.

    alternate text
  18. Connect the crimp lug side of the red wire diameter 3 mm on the red banana plug with a nut (provided with the red banana plug).

    alternate text
  19. Connect the crimp lug side of the black wire diameter 3 mm on the black banana plug with a nut (provided with the black banana plug).

    alternate text
  20. Take the other side of the red wire diameter 3 mm, and connect it on the Vin port of the MKR CONNECTOR CARRIER with the other side of the red wire connected to the voltage divider board.

    alternate text
  21. Take the other side of the black wire diameter 3 mm, and connect it on the GND port of the MKR CONNECTOR CARRIER with the other side of the black wire connected to the voltage divider board.

    alternate text
  22. Drill a 14 mm diameter hole on one side of the box, and insert in the push button. Use a nut to fix it (the nut is provided with the push button).

    alternate text
  23. Connect both wire from the push button on the Grove screw terminal (one of the wire must be connect on the VCC port, and the other on the D2 port), then, screw it.

    alternate text
  24. Close the box. The flowmeter datalogger is ready to be use. Be careful, the datalogger need an 12V DC power supply, use an adapted power supply.

alternate text